Acrylic Fiberglass Sleeving — Grade ARG
Acrylic-Coated Fiberglass Braid · 4 Grades
Technical datasheet · WCW (Shenzhen Wahchangwei Industrial Co., Ltd.)
DS-ARG-2026-01
Rev. 2026-10
UL File No. E233803
Construction: alkali-free (E) fiberglass braid coated with acrylic (polyacrylate) resin and cured. The coating bonds the braid into a smooth, crack-free wall that resists chemical solvents, oils and abrasion, and cuts cleanly without fraying. Among the earliest product series in China certified to UL and CUL — UL category UZFT2 / CUL UZFT8, a recognition held by only about ten companies worldwide. Available in all standard sizes and colors; custom constructions on request.
1 · Ratings & UL Recognition
| Model / UL File No. |
Test Std. |
Flame |
Temp. Rating |
Voltage Class |
Avg. Withstand |
Min. Individual |
| ARG-WCW-15 · E233803 | UL 1441 | UL VW-1 | −10 °C to +155 °C | D | 1500 V | 800 V |
| ARG-WCW-25 · E233803 | UL 1441 | UL VW-1 | −10 °C to +155 °C | C | 2500 V | 1500 V |
| ARG-WCW-40 · E233803 | UL 1441 | UL VW-1 | −10 °C to +155 °C | B | 4000 V | 2500 V |
| ARG-WCW-1U · E233803 | UL 1441 | UL VW-1 | −10 °C to +155 °C | A | 7000 V | 5000 V |
Dielectric values measured per UL 1441. “Min. Individual” is the minimum acceptable single-tube reading.
2 · Performance Parameters
| Test Item | Requirement / Result |
| Continuous service temperature range | −10 °C to +155 °C |
| Heat resistance | 190 °C ± 2 °C × 168 h — retains more than 1/2 of the original voltage value |
| Thermal aging | 190 °C × 6 h — no cracking |
| Cold bending | No cracking |
| Flame rating (UL VW-1 burning time) | < 30 seconds |
| Oil resistance | Oil-resistant |
3 · Dimensions
| Inner Diameter |
Minimum Wall Thickness |
| Nominal |
Tolerance |
Grade A |
Grade B / C / D |
| 0.5 – 2.5 mm | +0.25 / −0.00 mm | 0.38 mm | 0.20 mm |
| 3.0 – 4.5 mm | +0.30 / −0.00 mm | 0.45 mm | 0.23 mm |
| 5.0 – 6.0 mm | +0.40 / −0.00 mm | 0.45 mm | 0.28 mm |
| 7.0 – 9.0 mm | +0.55 / −0.00 mm | 0.50 mm | 0.32 mm |
| 10.0 – 14.0 mm | +0.75 / −0.00 mm | 0.60 mm | 0.40 mm |
| 15.0 – 25.0 mm | +0.85 / −0.00 mm | 0.64 mm | 0.43 mm |
Wall thickness values are minimums per UL 1441 by voltage class. Standard colors and custom colors available on request; custom cut lengths quoted on request.
4 · Typical Applications
Transformer and coil lead insulation, inverters, wind generators and compressor motors — anywhere leads run through oil-immersed or solvent-laden environments, where the acrylic coating keeps the dielectric wall stable. The smooth coated braid also suits wiring bundles that need abrasion protection with a tight bend radius.
5 · Compliance & Documents
| UL recognition | UL 1441 — File No. E233803 (ARG-WCW series) · UL category UZFT2 / CUL UZFT8 |
| Flame rating | UL VW-1 |
| Quality system | ISO 9001:2015 · IATF 16949:2016 · ISO 14001:2015 · ISO 45001:2018 |
| On request | RoHS, REACH SVHC, halogen-free statements; certificate copies for supplier qualification and PPAP |