UL / CUL Certified Since 2003  ·  IATF 16949:2016  ·  4 Bases  ·  60+ Export Countries wcw-sz@szwcw.com
WCW logo

Silicone Rubber Fiberglass Sleeving — Grade SRG
Inside Rubber / Outside Fiber

Technical datasheet · WCW (Shenzhen Wahchangwei Industrial Co., Ltd.)
DS-SRG-2026-01
Rev. 2026-10
UL File No. E233803
Construction (inside rubber / outside fiber): extruded silicone rubber tube, over-braided with alkali-free (E) fiberglass yarn and finished with silicone resin. The soft rubber inner wall fits closely over irregular shapes; the outer fiberglass braid adds abrasion and mechanical protection. Available in all standard sizes, colors and voltage classes; custom constructions on request.

1 · Ratings & UL Recognition

Model / UL File No. Test Std. Flame Temp. Rating Avg. Withstand Min. Individual
SRG-70 · E233803UL 1441UL VW-1−10 °C to +200 °C7000 V6000 V

Dielectric values measured per UL 1441. “Min. Individual” is the minimum acceptable single-tube reading.

2 · Performance Parameters

Test ItemRequirement / Result
Continuous service temperature range−10 °C to +200 °C
Heat resistance265 °C ± 2 °C × 168 h — retains more than 1/2 of the original voltage value
Thermal aging260 °C × 6 h — no cracking
Cold bendingNo cracking
Horizontal burning< 30 seconds
Flame rating (UL VW-1 burning time)< 30 seconds
Hydrolysis stabilityNo stickiness, no deformation, no softening

3 · Dimensions

Inner Diameter Wall Thickness
Nominal Tolerance 7000 V
1.0 – 2.5 mm+0.20 / −0.00 mm0.60 ± 0.05 mm
3.0 – 5.0 mm+0.30 / −0.00 mm0.70 ± 0.05 mm
6.0 – 7.0 mm+0.35 / −0.00 mm0.75 ± 0.05 mm
8.0 – 9.0 mm+0.40 / −0.00 mm0.80 ± 0.05 mm
10.0 – 12.0 mm+0.50 / −0.00 mm0.90 ± 0.05 mm
13.0 – 25.0 mm+0.65 / −0.00 mm1.30 ± 0.05 mm

Standard color: white; other colors available on request. Custom cut lengths and custom constructions quoted on request.

4 · Typical Applications

Appliance thermostats and heating elements, welding robots and high-temperature automation, high-voltage harnesses, transformer and coil lead insulation, marine and specialty lighting — wherever the lead must be protected mechanically as well as electrically. The braided outer surface resists abrasion in moving or bundled wiring.

5 · Compliance & Documents

UL recognitionUL 1441 — File No. E233803 (SRG-70)
Flame ratingUL VW-1
Quality systemISO 9001:2015 · IATF 16949:2016 · ISO 14001:2015 · ISO 45001:2018
On requestRoHS, REACH SVHC, halogen-free statements; certificate copies for supplier qualification and PPAP
WCW · Shenzhen Wahchangwei Industrial Co., Ltd. — source manufacturer since 2002. UL / CUL certified since 2003, IATF 16949:2016, exporting to 60+ countries.
Your contact: Liming Wu (Andy), Sales Manager · Email wcw-sz@szwcw.com · Tel / WhatsApp +86 150 1354 6673 · HQ: No.25 Langbei 6th Industrial Area, Baolong Street, Longgang, Shenzhen 518111, China.
Data believed accurate as of the revision date; confirm critical values against the current UL file and your own qualification testing.