Silicone Rubber Fiberglass Sleeving — Grade SRG
Inside Rubber / Outside Fiber
Technical datasheet · WCW (Shenzhen Wahchangwei Industrial Co., Ltd.)
DS-SRG-2026-01
Rev. 2026-10
UL File No. E233803
Construction (inside rubber / outside fiber): extruded silicone rubber tube, over-braided with alkali-free (E) fiberglass yarn and finished with silicone resin. The soft rubber inner wall fits closely over irregular shapes; the outer fiberglass braid adds abrasion and mechanical protection. Available in all standard sizes, colors and voltage classes; custom constructions on request.
1 · Ratings & UL Recognition
| Model / UL File No. |
Test Std. |
Flame |
Temp. Rating |
Avg. Withstand |
Min. Individual |
| SRG-70 · E233803 | UL 1441 | UL VW-1 | −10 °C to +200 °C | 7000 V | 6000 V |
Dielectric values measured per UL 1441. “Min. Individual” is the minimum acceptable single-tube reading.
2 · Performance Parameters
| Test Item | Requirement / Result |
| Continuous service temperature range | −10 °C to +200 °C |
| Heat resistance | 265 °C ± 2 °C × 168 h — retains more than 1/2 of the original voltage value |
| Thermal aging | 260 °C × 6 h — no cracking |
| Cold bending | No cracking |
| Horizontal burning | < 30 seconds |
| Flame rating (UL VW-1 burning time) | < 30 seconds |
| Hydrolysis stability | No stickiness, no deformation, no softening |
3 · Dimensions
| Inner Diameter |
Wall Thickness |
| Nominal |
Tolerance |
7000 V |
| 1.0 – 2.5 mm | +0.20 / −0.00 mm | 0.60 ± 0.05 mm |
| 3.0 – 5.0 mm | +0.30 / −0.00 mm | 0.70 ± 0.05 mm |
| 6.0 – 7.0 mm | +0.35 / −0.00 mm | 0.75 ± 0.05 mm |
| 8.0 – 9.0 mm | +0.40 / −0.00 mm | 0.80 ± 0.05 mm |
| 10.0 – 12.0 mm | +0.50 / −0.00 mm | 0.90 ± 0.05 mm |
| 13.0 – 25.0 mm | +0.65 / −0.00 mm | 1.30 ± 0.05 mm |
Standard color: white; other colors available on request. Custom cut lengths and custom constructions quoted on request.
4 · Typical Applications
Appliance thermostats and heating elements, welding robots and high-temperature automation, high-voltage harnesses, transformer and coil lead insulation, marine and specialty lighting — wherever the lead must be protected mechanically as well as electrically. The braided outer surface resists abrasion in moving or bundled wiring.
5 · Compliance & Documents
| UL recognition | UL 1441 — File No. E233803 (SRG-70) |
| Flame rating | UL VW-1 |
| Quality system | ISO 9001:2015 · IATF 16949:2016 · ISO 14001:2015 · ISO 45001:2018 |
| On request | RoHS, REACH SVHC, halogen-free statements; certificate copies for supplier qualification and PPAP |