| Inner Diameter | Wall Thickness | Dielectric Withstand | Heat Resistance | Flame |
|---|---|---|---|---|
| 0.5 – 3.0 mm | 0.18 ± 0.05 mm | 300 – 700 V | −10 °C to +600 °C | UL VW-1 |
| 4.0 – 6.0 mm | 0.30 ± 0.05 mm | 300 – 700 V | −10 °C to +600 °C | UL VW-1 |
| 7.0 – 12.0 mm | 0.35 ± 0.05 mm | 300 – 700 V | −10 °C to +600 °C | UL VW-1 |
| 14.0 – 30.0 mm | 0.43 ± 0.05 mm | 300 – 700 V | −10 °C to +600 °C | UL VW-1 |
Ratings apply across the full size range. Wall thickness is nominal ± tolerance as shown.
Hot-runner systems and manifold zones in plastics processing, smelting and casting equipment, automotive engine bays and exhaust-adjacent harnesses, ovens, air-fryer and heating appliances, continuously hot machinery — anywhere lead protection must survive sustained +600 °C service while the wire inside keeps its own insulation. The smooth braid also slides easily over bundles during assembly.
| Flame rating | UL VW-1 |
| UL recognition | Not UL-filed — TGS is specified for thermal protection duty beyond UL temperature class scope; ask us for third-party test reports where required |
| Quality system | ISO 9001:2015 · IATF 16949:2016 · ISO 14001:2015 · ISO 45001:2018 |
| On request | RoHS, REACH SVHC, halogen-free statements; certificate copies for supplier qualification and PPAP |